Type of pressure
|
gauge
|
Package type
|
DIP-6
|
Pressure medium
|
Air or non-corrosive gas and water
|
|
Min
|
Nominal
|
Max
|
Unit
|
Excitation Voltage
|
--
|
5
|
|
VDC
|
Excitation Current2
|
--
|
2.5
|
|
mA
|
Pressure Range
|
5,5.8,8,10,15,30,50,100
|
Psi
|
||
Offset
|
0.45
|
0.50
|
0.55
|
VDC
|
Span
|
3.95
|
4.00
|
4.05
|
VDC
|
Output Current of Buffer
|
|
|
2.2
|
mA
|
Accuracy3
|
|
±0.3
|
|
%FS
|
Over pressure
|
|
|
3X
|
Rating
|
Temp-Compensating
|
0
|
|
50
|
℃
|
Temp-Operating
|
-20
|
|
+85
|
℃
|
Temp-Storage
|
-40
|
|
+125
|
℃
|
|
|
|
|
|
1、Unless otherwise specified, all parameters are measured at 25 °C and excitation of 5 Vdc
2. Combined error measured over 0 to 50 °C
3. Wetted material containing glass, RTV, , PPA and siliocn
|